Description
Centralized ventilation system for large home or offices.- Can be used in large houses (4-5 bedrooms) up to 450 m³/h at 150 Pa
- Mechanically supplied fresh air
- Mechanically drainage of used air
- Demand-driven ventilation thanks to integrated air quality sensors
- High-efficiency heat exchanger for reduced heat losses
- Integrated TouchDisplay in front panel
- Control via Endura® Delta App (iOS, Android) on smartphone and tablet
Technical specifications
PRODUCT CHARACTERISTICS
Efficiency
- 87% at 100 m³ / h (27 l / s)
- 83% at 250 m³ / h (70 l / s)
- 81% at 350 m³ / h (97 l / s)
- 79% at 450 m³ / h (125 l / s)
EPB product data
- Max. capacity: 450 m³/h at 150 Pa
- Integrated plastic counter flow heat exchanger
- Maximum power consumption: 2 x 115 W
Ventilation system
- Ventilators
- 2 EC motors
- Supply voltage: 1 x 230V / 50Hz
- Constant flow control: airflow remains constant
- Dimensions (Height x Width x Depth)
- 862 x 747 x 520 mm
- Weight
- 46 kg
- Available types
- 4 upper connections (T4)
- 2 upper and 2 lower connections (T2/B2)
- Standard left-hand model, possible to convert to right-hand model (Contact us for more information)
- Closing of the heat exchanger during warm weather
- Direct join to the unit:
- EPP ducts: outer diameter 180 mm, inner diameter 150 mm
- EPP ducts: with connecting sleeve: outer diameter 210 mm, inner diameter 180 mm
- Other ducts: 180 mm diameter can be connected directly onto the ventilation system
- Integrated condensation drain Ø32 mm
- 2 x coarse (G4) cartridge filters (PM1 (F7) optional for supply)
- Maintenance-friendly
- Large filter surface area
- Integrated TouchDisplay in front panel
- Touchscreen
- Possibility to configure and control ventilation unit
- Error feedback
- Filter message
- Visualization of current ventilation conditions
- Ethernet connection (RJ45 connector)
- Possibility to control unit via tablet / smartphone via local network
- External input/output contacts
- Open input contact (digital 0-24 V)
- Supply and extract disabling option – e.g. emergency OFF to switch off supply flow rate
- Supply switch-off
- Drainage switch-off
- Activation of fireplace function via external contact
- Open output contact (digital 0-24 V)
- Error message
- Filter message
- 0-10V analogue input
- 0-10V analogue output
FUNCTIONS
- Operation
- According to automatic mode (program)
- Manual control
- Timers
- Via integrated air quality sensors (RH, CO2 & VOC)
- Via optional, external air quality sensors
- Air quality sensors
- Relative humidity
- VOC (volatile organic compounds)
- CO2
- Ventilation levels adapted in accordance with measured air quality
- Frost protection
- Automatic temporary imbalance and flow restriction to prevent freezing of the heat exchanger
- Electrical pre-heating element
- Modular power
- Max. power: 1000 W
- Breeze function
- Breeze function for optimum cooling in summer (summer bypass with adjustable ventilation level)
- Automatic and manual bypass activation
- 4-seasons automatically controlled indoor temperature
- Fireplace function
- Activated via external pulse switch
- Temporary imbalance on supply side (overpressure) to aid ignition process
- Holiday mode
- Input of start and end dates during prolonged absence
- System ventilates at maximum energy efficiency
- Filter message / notification
- Via smartphone
- On external control unit (optional)
- Timer-controlled
CONTROL
- With Endura Delta app
- iOS, Android
- Smartphone and tablet
- TouchDisplay on unit
- Power and communication with motor unit via RS232
- Possibility to program the motor unit with the TouchDisplay